Table 3-21     Problems resolved in versions prior to XCP 2050 (continue d)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
121219-016
RTIF2-
x
121219-017
RTIF2-
x
121219-018
RTIF2-
x
x
x
121219-019
RTIF2-
x
130109-002
RTIF2-
x
x
x
130109-005
Description
An "internal error" may occur if the
prtfru(8) command is executed while
powering on/off or resetting the physical
partition (PPAR).
If a SPARC M10-4S chassis is powered
off after an error log is registered because
a memory error occurred in BB#00 or
BB#01, the same error log may be
registered again.
In a system in which two or more SPARC
M10-4S chassis units constitute multiple
physical partitions (PPARs), if you power
on the PPAR after switching the master
XSCF as a result of any of the following,
error logs of
"STICK does not start (CPU)",
"STICK does not start (MBC)",
or "STICK count up error" may be
registered, causing degradation of the
CPU memory units (CMUU/CMUL).
- Performing firmware update
- Detecting an XSCF failure
- Executing the switchscf(8) command
When a PCI card is inserted to or
removed from a PCI expansion unit, a
number that is different from the relevant
PCI card number (PCI#) is displayed in
the log. In addition, when error log
"PCICARD failed" is registered due to an
error with the PCIe slot on the PCI
expansion unit or the PCI card, a number
other than that of the relevant PCI card
number (PCI#) is displayed in the error
log.
If "Console path is switched" is registered
in the event log of a system in which the
physical partition (PPAR) consists of
multiple system boards (PSBs), the
PPAR-ID may have an invalid value.
If you use the replacefru(8) command to
replace a power supply unit (PSU),
"Indispensable parts are not installed
(PSU)" may be registered in the event log.
Workaround
Wait for the power on/off or reset of the
PPAR to complete and then execute the
prtfru(8) command again.
There is no effective workaround.
There is no effective workaround.
After switching of the master XSCF is
performed, power off the input power
supply of all SPARC M10-4Ss and power
them on again, without powering on the
PPAR.
Read it as the number obtained by
subtracting one from the PCI number
(PCI#) displayed in the log.
There is no effective workaround.
This is an error log that is registered
because a PSU is removed. Ignore it.