Table 3-15     Problems resolved in XCP 2090 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
131112-014
RTIF2-
x
131112-015
RTIF2-
x
x
x
131126-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
120
Description
If the following mail server is being used
and REMCS registration or REMCS
environment setting is performed, a
communication timeout with the mail
server is detected, causing processing to
fail.
- Windows ExchangeServer
- E-PORT
- qmail
If the initbb(8) or replacefru(8) command
is executed, an event log stating "Change
Master Failed" may be registered.
Suppose that a system satisfying one of
the conditions described in [Conditions]
sets the power supply interlocking
function. If Oracle Solaris is running and
one of the events mentioned in [Event]
occurs, an external I/O device may be
erroneously powered off.
[Conditions]
- A single SPARC M10 system is
registered in the power supply
interlocking group.
- Multiple SPARC M10 systems are
registered in the power supply
interlocking group, and the physical
partitions other than those of the
SPARC M10 system that resets the
XSCF are powered off.
[Event]
- Firmware update was executed from
the flashupdate(8) command and XSCF
Web, and the XSCF was reset.
- The XSCF was reactivated from the
rebootxscf(8) command and XSCF Web,
and the XSCF was reset.
- The XSCF was reset because of a failure.
Workaround
After changing the mail server to be used
to sendmail or postfix, perform REMCS
registration or REMCS environment
setting. If it is difficult to change the mail
server, update its firmware to XCP 2090
or later.
There is no effective workaround.
Ignore the event log.
Apply either of the following
countermeasures:
- Before firmware update or XSCF
reactivation, execute the setremotepwrmgmt
-c disable command to disable the
power supply interlocking function.
Subsequently, update the firmware or
reactivate the XSCF. After the XSCF has
been activated, execute the
setremotepwrmgmt -c enable
command to enable the power supply
interlocking function.
- Disable the power supply interlocking
function with the setremotepwrmgmt
-c disable command and then manually
power on the external I/O device.