Fujitsu M10 Product Notes page 146

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-17     Problems resolved in XCP 2070 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
130903-006
RTIF2-
x
x
x
130903-007
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
132
Description
If multiple physical partitions (PPARs)
exist in a system consisting of multiple
SPARC M10-4S units, and some SPARC
M10-4S units are turned off and then on
again, an "SRAM Serious Error" may
occur, requiring the replacement of the
CPU memory unit lower (CMUL). When
the state is displayed with the
showpparstatus(8) command or the
showdomainstatus(8) command, the
PPAR state may not be displayed
correctly.
If the setcod(8) command is executed
repeatedly on the physical partition
(PPAR) in the PowerOn state, the
resources available within the process
may be exhausted, and codd may cause a
process down.
Workaround
There is no effective workaround.
While a PPAR is operating, do not turn
off the SPARC M10-4S. Use the
poweroff(8) command, for example, to
stop a PPAR before turning it off.
You can avoid this by executing setcod(8)
when PPAR is in the PowerOff state.
[How to restore]
Restart codd.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents