Table 3-12     Problems resolved in XCP 2210 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
131213-004
RTIF2-
x
131213-008
RTIF2-
x
131213-009
RTIF2-
x
131213-021
Description
If the PPAR DR feature is enabled/
disabled on XSCF Web, selecting the
[PPAR Operation] - [PPAR Mode
Configuration] menu , selecting
PPAR-DR(Current) or PPR-DR(Next)
and clicking [Configure], a wrong
dialogue box appears and the PPAR DR
feature is not enabled / disabled.
In a configuration with 3 or more BBs, or
with crossbar boxes, after XSCF
switchover occurs due to some problems
on the master XSCF while the "addboard
-c configure" command is running, the
deleteboard(8) command, executed on
the new master XSCF may not get any
response. This symptom occurs if two
master XSCFs exist on a system after a
master/standby switchover of XSCFs.
(Reference: RTIF2-131213-001)
This state can be confirmed by a lighted
MASTER LED at the rear panel of two
chassis.
The "Failed to evacuate board resources"
message may be output when the
addboard(8) or deleteboard(8) command
of the DR feature is executed and the
addition or removal of system boards
with DR feature fails.
The timeout error log "Timeout detected
during unconfiguration of PSB#xx-x."
may be registered and an abnormal
termination may occur when a system
board (PSB) is removed by the
deleteboard(8) command of the DR
feature. In such a case, the showboards(8)
command shows that the status of all the
Pwr/Conn/Conf of the system board
(PSB) is "y".
Workaround
Execute the XSCF setpparmode(8)
command to enable/disable the PPAR DR
feature.
There is no effective workaround.
[How to restore]
Execute the deleteboard(8) command
when the number of master XSCFs
automatically returns to one after a few
minutes.
If the number of master XSCFs does not
return to one even after 15 minutes, press
the RESET switch at the rear panel of all
existing SPARC M10 system and crossbar
boxes. Execute the deleteboard(8)
command after that.
Re-execute the addboard(8) or
deleteboard(8) command. If it fails again,
either reboot the control domain or
reboot the XSCF with the "rebootxscf –a"
command. After that, re-execute the
addboard(8) or deleteboard(8) command
of the DR feature.
There is no effective workaround.
[How to restore]
Reboot all the XSCFs by executing the
"rebootxscf -a" command.