Table 3-15     Problems resolved in XCP 2090 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
131129-001
RTIF2-
x
x
x
131213-006
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
122
Description
If there is a mounted memory, the last
eight digits of whose "Code" start with
"00", as displayed by the showhardconf
(8) command in, execution of any of the
following actions may result in incorrect
display, showing a value of 0 for both the
"Code" and the "Size" of that memory, as
shown.
- Execute the restoredefaults factory
command
- Execute the initbb(8) command
- Change the mounting point of memory
[Example]
XSCF>showhardconf
:
MEM#10B Status:Normal;
+ Code:ce8001M393B2G70QH0-YK0
0000-00511571;
+ Type:07; Size:16 GB;
XSCF>showhardconf
:
* MEM#10B Status:Deconfigured;
+ Code:000000 0000-00000000;
+ Type: ; Size:0 GB;
The "LDC Protocol info from PPAR
(PPAR ID X : Domain Service Data Send
Failed)" event log is registered on a
running logical domain and shutdown of
that logical domain may not be properly
executed.
Workaround
Apply the latest version of the XCP, and
then execute power off and on.
There is no effective workaround.
Either reboot the control domain or
execute the "rebootxscf -a" command to
reboot XSCF.