Fujitsu M10 Product Notes page 132

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-15     Problems resolved in XCP 2090 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
131112-002
RTIF2-
x
x
x
131112-003
RTIF2-
x
x
x
131112-008
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
118
Description
Suppose that the system uses a crossbar
box and contains two or more physical
partitions (PPARs) each consisting of 2BB
or more. In this system, if a hardware
failure that affects all the PPARs occurs,
the failed part is degraded such that the
PPAR reactivation processing may fail,
causing all the PPAR power supplies to
remain turned off.
If the testsb(8), diagxbu(8), or flashupdate
-c sync command is executed during the
execution of the flashupdate(8)
command, the error log "FMEM serious
error" is registered, and the testsb(8),
diagxbu(8), or flashupdate -c sync
command may fail.
Suppose that the error log "SCF
Diagnosis error on System backup
memory" is registered, which is related to
the PSU backplane (PSUBP) or XSCF
interface unit (XSCFIFU). The FRU of the
error log registered immediately after
that error log may not be correct.
In this case, any one of the following
messages is displayed to indicate that the
FRU PSUBP or XSCFIFU is not correct.
Msg: SCF Diagnosis initialize RTC
FRU: PSUBP or XSCFIFU
or
Msg: SCF Diagnosis error on XXXX
FRU: PSUBP or XSCFIFU
XXXX indicates any of the following FRUs:
CPU, L2 cache, SDRAM, RTC, SPI
FMEM, NAND
Workaround
There is no effective workaround.
The failed parts are degraded.
Power on the PPAR again.
Do not execute the testsb(8), diagxbu(8),
or flashupdate -c sync command while
the flashupdate(8) command is being
executed.
To confirm the completion of the
flashupdate(8) command, execute the
showlogs event command and then
check for the following message.
XCP update has been completed (XCP
version=xxxx:last version=yyyy)
There is no effective workaround.
Replace the FRU as follows.
For SPARC M10-1: FRU: /MBU
For SPARC M10-4: FRU: /BB#00/CMUL
For SPARC M10-4S: FRU: /BB#xx/CMUL
or FRU: /XBBOX#xx/XSCFU

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc m10

Table of Contents