Table 3-6     Problems resolved in XCP 2240 (continued)
SPARC M10-
RTINo.
1
4
4S
RTIF2-
x
x
x
140507-013
RTIF2-
x
140515-001
RTIF2-
x
140523-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
84
Description
Even if two default gateways are set up
using the setroute(8) command,
connection from other networks is
possible only on either XSCF-LAN#0 or
XSCF-LAN#1.
In order to configure the XSCF startup
mode function, after changing the startup
mode with the xscfstartupmode(8)
command or setting the operation panel
mode switch to "Locked" or "Service", if
the rebootxscf(8) command is executed to
reset XSCF, the new startup mode gets
enabled. However, under normal
circumstances, the configuration of the
startup mode is not enabled when XSCF
is reset using the rebootxscf(8) command.
It is enabled only when the input power
of the system is turned off/on (AC
OFF/ON).This state can be confirmed by
the "xscfstartupmode -d" command, as
follows:
[Example] When startup mode is set to
"fast" after setting the operation panel
mode switch to "Locked"
XSCF> xscfstartupmode -d
Setting Mode: normal
Current Mode: normal
XSCF> xscfstartupmode -m fast
XSCF> rebootxscf -a
XSCF> xscfstartupmode -d
Setting Mode: fast[need AC OFF/ON]
Current Mode: fast
However, the correct result will be that
the "Current Mode" be "normal" like the
following:
XSCF> xscfstartupmode -d
Setting Mode: fast [need AC OFF/ON]
Current Mode: normal
In the event of an instantaneous power
failure lasting 11 ms or more, the CHECK
LED on the operation panel will remain
on after recovery, and the XSCF may not
start.
Therefore, even if the system is set to
automatically start after recovery, it may
not actually start automatically.
Workaround
Among XSCF-LAN#0 and XSCF-LAN#1,
use the IP address of the gateway that
can be connected to.
There is no effective workaround.
There is no effective workaround.
[How to restore]
After turning off the input power, wait
for at least 10 seconds before turning it
on again.