Table 3-12     Problems resolved in XCP 2210 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140212-015
RTIF2-
x
140212-017
RTIF2-
x
x
x
140212-018
RTIF2-
x
x
x
140212-019
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
110
Description
If the version(8) command is executed
after replacing the CPU memory unit
lower (CMUL), XSCF unit (XSCFU) or
the motherboard unit (MBU), the state of
"Current Bank" and "Reserve Bank" is
wrongly displayed.
[Example]
- Before replacing CMUL
XSCF> version -c xcp
BB#00-XSCF#0 (Master)
XCP0 (Reserve): 2210
XCP1 (Current): 2210
- (Wrong) After replacing CMUL
XSCF> version -c xcp
BB#00-XSCF#0 (Master)
XCP0 (Reserve): 2210
XCP1 (Current): 2210
- (Right) After replacing CMUL
XSCF> version -c xcp
BB#00-XSCF#0 (Master)
XCP0 (Current): 2210
XCP1 (Reserve): 2210
After removing SPARC M10-4S or
crossbar boxes (XBBOX) with the
initbb(8) or the replacefru(8) commands,
if the XSCF network (host and domain
names, SSCP, IP address, routing, name
server) is setup and the applynetwork(8)
command is executed, the "An internal
error has occurred. Please contact your
system administrator" error message is
output and the XSCF network
parameters are not enabled.
In the REMCS customer information
input screen, if any of the following
two-byte characters are input in the
two-byte input field, input error message
may be output.
- The leading character corresponds to
A1xx of the EUC code.
- The trailing character corresponds to
xxA1 of the EUC code.
When turning on the input power, the
voltage reading of the power supply unit
(PSU) fails and the PSU error "Hardware
access error" may be mistakenly detected
and the PSU is degraded.
Workaround
There is no effective workaround.
It will not affect the system as it is only a
problem of the command output.
[How to restore]
Re-execute the flashupdate(8) command.
There is no effective workaround.
[How to restore]
After re-connecting or replacing the
removed SPARC M10-4S or XBBOX, set
up the XSCF network again.
Do not input the two-byte characters at
the beginning and end of the character
strings, which produce errors.
There is no effective workaround.
[How to restore]
Ignore this error log. To dissolve the
degraded state of the PSU, turn off the
input power and turn it on again.