Table 3-9     Problems resolved in XCP 2230
SPARC M10-
RTINo.
1
4
4S
RTIF2-
x
140212-009
RTIF2-
x
140527-001
RTIF2-
x
x
x
140606-002
RTIF2-
x
x
x
140606-003
RTIF2-
x
x
x
140606-006
Description
When the XSCF is under high load due to
high volume of packets sent to the XSCF
network by the L2 loop etc., the false
error "Hardware access error" regarding
the power unit (PSU) is detected.
Moreover, the PSU is marked as failed
due to this error.
On a system that is configured with
several SPARC M10-4S, if XSCF
rebooting is not performed with the
rebootxscf(8) command or if the input
power is not turned off for about 10 days
in respect to the XSCFs of the following
status, the "XSCF self-diagnosis warning
detection" error message is logged:
- A standby XSCF which did not perform
master/standby switchover for about 10
days.
- Slave XSCF.
Even though the "AEV_
AUTHENTICATE" audit event is
enabled, XSCF Web login failure events
are not registered in the audit log.
When an attempt is made to look at an
audit log concerning XSCF Web
operation using the viewaudit(8)
command, the command displays
incorrect values. The displayed values of
the port number and IP address at the
time of XSCF Web access are "0" and
"0000".
When specifying a system board (PSB)
for a logical system board (LSB) on the
[PPAR Operation] - [PPAR Configuration]
screen of XSCF Web, you need to note
the following: A PSB cannot be specified
if it has already been assigned to another
physical partition (PPAR).
Workaround
If the reason for the high load is the L2
loop, eliminate the root cause by
reviewing the network connection etc.
[How to restore]
To clear the failure mark on PSU, turn off
the input power and then turn it back on.
There is no effective workaround.
Please ignore this message.
There is no effective workaround.
There is no effective workaround.
For the setting, use the setpcl(8)
command of the XSCF shell.
Chapter 3 Information on Software