Fujitsu M10 Product Notes page 112

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-11     Problems resolved in XCP 2220 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140212-004
RTIF2-
x
x
x
140212-006
RTIF2-
x
x
x
140212-022
RTIF2-
x
140221-003
RTIF2-
x
x
x
140227-003
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
98
Description
The OID information of
"scfPPAROsMachine" in the definition
file of XSCF extension MIB should have a
value of "sun4v", but instead, it contains
the CMU firmware version information
like "02090000".
In case of SNMPv1 or SNMPv2, if the
trap host name, which contains the XSCF
host name, is registered by the
setsnmp(8) command, the trap host is not
displayed by the showsnmp(8) command.
[Example of non-displaying with the
showsnmp(8) command]
XSCF host name: example.com
Trap host name: test.example.com
If the trap host is registered by specifying
the trap type with the "-t" option as
"inform", to the "setsnmp addtraphost"
command, the UDP address of the trap
that is reported to the trap host, becomes
the IP address that is assigned to the
XSCF-LAN (physical IP address), instead
of the takeover IP address (virtual IP
address). This symptom occurs when a
takeover IP address is set up.
If the addboard(8) or deleteboard(8)
command is executed using the DR
feature, addition or removal of system
boards using the DR feature may fail
with displaying the following message:
Failed to evacuate board resources
After the detection of a degradation of
SPARC M10 chassis, if reboot or AC
OFF/ON is executed on the physical
partitions, the "PSU shortage" error
message may be mistakenly registered.
Moreover, when the error is detected, a
"Failure" mark is attached to the PSU.
Workaround
There is no effective workaround.
Either specify a trap host name which
does not contain the XSCF host name or
specify the IP address of the trap host.
There is no effective workaround.
Re-execute the addboard(8) or
deleteboard(8) command. If it fails again,
either reboot the control domain only or
reset XSCF using the "rebootxscf -a"
command. After that, re-execute the
addboard(8) or deleteboard(8) command,
using the DR feature.
There is no effective workaround.
[How to restore]
Execute the following procedures.
- If the "Status" of the power supply unit
(PSU) has not become "Faulted":
1. Eliminate the cause of the degradation
of SPARC M10 chassis.
2. If a "Failure" mark is attached to the
PSU, perform AC OFF/ON to remove
it.
- If the "Status" of the power supply unit
(PSU) has become "Faulted":
1. Replace the PSU.
2. Perform AC OFF/ON to remove the
"Failure" mark from the PSU.