Table 3-20     Problems resolved in XCP 2050 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
130319-003
RTIF2-
x
130329-004
RTIF2-
x
130329-006
RTIF2-
x
x
x
130516-003
Description
If the shutdown -i5 command and
power-off command compete for
power-off of the PPAR when the former
is executed in the control domain or the
latter is executed from the ok prompt
while power-off of the physical partition
(PPAR) is performed with the poweroff
(8) command, "SCF:PPAR issued
power-off request (PPARID X)" may be
registered many times.
In a system with building block
configuration, if the following operations
are performed during power-on of the
physical partition (PPAR), connection to
the control domain console may not be
possible.
1. XSCF for any of the SPARC M10-4S
units constituting PPAR is reset.
2. Switching of the master XSCF and
standby XSCF occurs.
3. XSCF of the SPARC M10-4S that was
reset in 1. is reset again.
If XSCF of SPARC M10-4S belonging to
the physical partition (PPAR) in
operation is reset due to a panic or
watchdog timeout while the master XSCF
and the standby XSCF are restarting
simultaneously, connection to the control
domain console may not be possible.
If the XSCF load is high, the following
warning message may be output,
indicating the power supply unit (PSU)
as a suspected location.
Insufficient FAN rotation speed
PSU voltage out of range error
PSU output current too high
PSU over temperature warning
Workaround
Ignore the registered event log, because
the PPAR has been normally powered off.
There is no effective workaround.
Reset the master XSCF using the
switchscf(8) command.
There is no effective workaround.
Power off the PPAR by using the
poweroff -f command, and then power it
on again.
There is no workaround.
This is a warning message, so you can
operate it as it is. Ignore the message.