Problems Resolved In Xcp 2080 - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-15     Problems resolved in XCP 2090 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
140605-003
RTIF2-
x
140605-004
RTIF2-
x
x
x
140617-001

Problems resolved in XCP 2080

The following table lists the problems resolved in XCP 2080.
Description
Suppose that an XSCF failure occurs on
one SPARC M10-4S chassis in a physical
partition (PPAR) and the CHECK LED is
on and the READY LED is off on the
XSCF. If you attempt to power on this
PPAR, the system erroneously judges
that an error has occurred on every
SPARC M10-4S chassis in this PPAR and
you cannot power on the PPAR.
When you add or replace one SPARC
M10-4S chassis (BB#00 or BB#01) or
crossbar box chassis (XBBOX#80 or
XBBOX#81), power control schedule
settings for automatic power-on/off are
not synchronized between the existing
and additional/replacement chassis.
If master/standby XSCF switching is
performed in this state, automatic
power-on/off is not performed because
the power control schedule settings
remain unavailable.
When the showhardconf -u command is
executed on a system connected to a PCI
expansion unit, the number of PCI cards
installed on the PCI expansion unit is
erroneously displayed as "11" (the
maximum number of cards that can be
installed).
Workaround
There is no effective workaround.
Follow the maintenance procedure for
XSCF failures to replace the CPU
memory unit lower (CMUL) on the faulty
SPARC M10-4S chassis.
There is no effective workaround.
Execute the following procedure to
synchronize power control schedule
settings for automatic power-on/off
between the master and standby XSCFs:
1. Execute the showpowerschedule -m
list command to confirm that the power
control schedule has been registered.
If no power control schedule has been
registered, re-register it by using the
addpowerschedule(8) and
setpowerschedule(8) commands.
2. Execute the setpowerschedule -c
control command to enable or disable
the power control schedule.
There is no effective workaround.
To confirm information on PCI cards
installed on the PCI expansion unit,
execute the showhardconf(8) command
with no options.