Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140227-004
RTIF2-
x
140227-005
RTIF2-
x
x
x
140227-009
RTIF2-
x
140227-010
RTIF2-
x
140304-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
54
Description
If a link card is removed from the system
by PCI hot plugging (PHP), using the
cfgadm(1M) command on the logical
domain on which it is mounted, and thus
power supply to it is stopped, the "LINK
CARD 12C error" log may be mistakenly
registered.
At the time of cold replacement or cold
addition of CPU memory unit lower
(CMUL) or SPARC M10 chassis, if the
following conditions are met, the "XCP
firmware version synchronization failed"
message may be registered to the event
log and maintenance or addition fails.
- Two or more CMUL or SPARC M10
chassis is cold replaced or cold added
at one time.
- The XCP versions of replacement
components do not match the version
of the master XCP.
If XSCF login is performed with a XSCF
user account, whose privileges are
managed by a LDAP server, specified by
the setldap(8) command, execution of
commands in the XSCF shell or
operations on the XSCF Web may take a
while.
The following improper error message is
displayed when the "addboard -c
configure" command is executed,
specifying a non-existent system board
(PSB):
PPAR is currently unavailable for DR,
because XBU status has failed
Or
The current configuration does not
support this operation
When performing AC OFF/ON, in some
very rare cases. the "SCF process down
detected" error message is registered and
XSCF fails to start.
Workaround
There is no effective workaround.
Ignore this error log. Power supply to the
link card has been stopped for sure and
the system can be operated continuously.
When cold replacing or cold adding two
or more CMUL or SPARC M10 chassis,
use the replacefru(8) or addfru(8)
command to perform the operations one
by one.
[How to restore]
Execute any of the following procedures.
- Procedure 1
1. Perform AC OFF/ON
2. Execute the flashupdate(8)
command, specifying the XCP version.
XSCF> flashupdate -c update -m xcp -s
xxxx -f
xxxx is the XCP version of the master
XSCF
- Procedure 2
Execute the replacefru(8) command to
perform a pseudo replacement of the
CMUL or SPARC M10 chassis that
failed to be cold replace.
In case of a LDAP server, specified by the
setldap(8) command, there is no effective
workaround.
Specify the LDAP server with the
setldapssl(8) command.
There is no effective workaround.
Execute the "addboard -c configure"
command, specifying existent PSBs.
There is no effective workaround.
If this symptom has occurred, contact the
maintenance staff.