Table 3-6     Problems resolved in XCP 2240 (continued)
SPARC M10-
RTINo.
1
4
4S
RTIF2-
x
x
x
141020-001
RTIF2-
x
141031-003
RTIF2-
x
x
x
141031-004
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
88
Description
When using the ASR function and an
abnormality occurs with the fan unit in
the PCI expansion unit or the SPARC
M10 system chassis, the following
incorrect fault telemetry is sent to ASR
Manager.
- An error in the fan unit of a PCI
expansion unit is sent as an error in the
fan unit of a SPARC M10 system chassis.
- An error in the fan unit of a SPARC
M10 system chassis is sent as an error
in the fan unit of a PCI expansion unit.
[Example] Error in fan unit of SPARC
M10 system chassis
- Incorrect
message ID: device.fan.toofast_pcibox
- Correct
message ID: device.fan.tooslow
This problem occurs when the fourth
byte from the beginning of the third field
of [Code:] at execution of the showlogs
error command is as shown below.
01911026、01911027、01911028、01911029、
0191102a、0191102b
[Example] Error in fan unit of PCI
expansion unit
- Incorrect
message ID: device.fan.tooslow
- Correct
message ID: device.fan.toofast_pcibox
This problem occurs when the fourth
byte from the beginning of the third field
of [Code:] at execution of the showlogs
error command is as shown below.
1100002E、1100002F
After the system board is deleted by
dynamic reconfiguration of physical
partitions (PPAR DR), I/O devices on I/O
domain may not work, or root domain or
I/O domain may cause a panic.
Hypervisor Abort may occur if all of
cores are degraded on primary domain.
Workaround
There is no effective workaround.
When the fourth byte from the beginning
of the third field of [Code:] as shown in
the [Example] in [Description] at
execution of the showlogs error
command, take action by interpreting the
message to be correct.
There is no effective workaround.
[How to restore]
If I/O devices does not cause a panic after
physical partitions (PPAR DR), reboot
the I/O domain.
There is no effective workaround.