Problems Resolved In Xcp 2210 - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Table 3-11     Problems resolved in XCP 2220 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
141106-002

Problems resolved in XCP 2210

The following table lists the problems resolved in XCP 2210.
Table 3-12     Problems resolved in XCP 2210
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
130801-002
RTIF2-
x
x
x
131126-005
RTIF2-
x
131212-001
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
106
Description
For XCP 2210 or earlier, the error log
"PCI Express link up failed" may be
erroneously registered, and an on-board
I/O device or a PCI slot may be degraded
if a physical partition (PPAR) is powered
on/off after any of the following error
logs related to abnormal temperature is
registered.
- Temperature out of range error
- High temperature at SW
- Hardware access error.(thermal sensor)
In these error logs, the first two bytes of
the second field in [Code:] has the value
of "0013".
Description
If a DIMM failure occurs, a configuration
error is erroneously detected and the
following event log is registered.
SCF:DIMM configuration error on
PSB#xx-0
The [Physical] or [Logical] tree displayed
in the menu frame is not updated even if
you click the [Refresh] button of the
masthead frame on XSCF Web.
If there is a physical partition (PPAR)
whose LSB number is 01 or larger, the
"showlogs error" command either does
not show the "I/O device error detected"
log even if I/O errors occur, or the FRU in
the "I/O device error detected" message is
displayed mistakenly.
Workaround
There is no effective workaround.
[How to restore]
Turn off the system input power, then
restore the power (AC-OFF/ON).
Workaround
There is no effective workaround.
Ignore this event log.
Using the maintenance procedure for
DIMM failures, turn off the input power
to the SPARC M10 system chassis in
which the failed DIMM is mounted,
replace the DIMM, and then turn on the
power. These steps will remove the
configuration error and failure.
Click the [Physical] or [Logical] tab of the
menu frame to redisplay the tree.
There is no effective workaround.