Table 3-11     Problems resolved in XCP 2220 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
140605-007
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
104
Description
For XCP 2041 or later, when an error log
for a configuration error in a power
supply unit (PSU) is registered,
inappropriate message text is registered
for this log. Although the message text
should indicate the mixing of different
AC input voltages (100 V and 200 V), it
indicates the existence of an incorrect
combination of PSU types.
[Example] Message text (to the right of
"Msg:") inappropriately registered when
different AC input voltages of 100 V and
200 V are mixed.
Code: 80000000-0001020000ff0000ff-
018af0220000000000000000
Status: Alarm Occurred: May 27
11:22:00.0000 JST 2014
FRU: /MBU
Msg: Wrong PSU is installed
The correct message indicating the
mixing of different AC input voltages is
as follows:
Msg: PSUs detected 100V and 200V at
AC inputs
Workaround
There is no effective workaround.
Execute the showlogs error command
and check the value of the third and
fourth bytes in the third field in [Code:].
Depending on this value, take
appropriate action by following the
correct message indicated below instead
of the output message.
- If the value of the bytes is "f022"
Different AC input voltages of 100 V
and 200 V are mixed on the PSU. Check
the PSU for AC input connection status.
- If the value of the bytes is not "f022"
The combination of PSU types is
incorrect. Contact a field engineer.