Table 3-5     Problems that might occur with XCP 2240 and workarounds (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
130305-001
RTIF2-
x
x
x
130305-002
RTIF2-
x
x
x
130305-007
RTIF2-
x
x
x
130305-013
RTIF2-
x
130305-020
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
42
Description
"The limit of power has been exceeded" is
registered in the event log if you perform
the following. Execute the
setpowercapping(8) command to set the
power consumption limiting function to
"Enable", the power consumption
maximum allowable value to "Specify
100 percent (default)", and the time
extension when exceeding the maximum
allowable power consumption to "none."
Then, turn on the input power supply or
turn off the power to the physical
partition (PPAR).
If an error in the CPU or memory is
detected and if the XSCF is switched
while the XSCF is notifying the error
information to the control domain, the
error information may not be notified
again to the control domain. Because of
this, the error information displayed with
the showlogs error command is not
displayed in the Fault Report output by
the fmdump command.
FRU registered in the error log is
displayed as "PPAR#30" if the configuration
error of the system board (PSB) is
detected when executing the testsb(8)
command or diagxbu(8) command.
While XSCF is starting, process down,
panic or watchdog timeout occurs, which
may cause XSCF to be reset.
If an XSCF panic or hang-up occurs, an
error log showing that "XSCF hang-up is
detected" may be posted many times.
Workaround
There is no effective workaround.
Ignore this event log.
There is no effective workaround.
Maintain according to the FRU displayed
by the showlogs error command.
There is no effective workaround.
Maintain the applicable PSB of SPARC
M10 system chassis.
Confirm that XSCF is successfully started.
If it is not started, turn off the power of
the physical partition (PPAR), and then
disconnect the input power supply to the
system and back on again (AC OFF/ON).
When recycling the power supply to the
system, wait for 30 seconds or more to
turn on the input power supply after
disconnecting.
In case XSCF is not started even if
recycling the input power supply to the
system, replace the CPU memory unit
lower (CMUL) or the motherboard unit
(MBU).
There is no effective workaround.
Ignore the logs with the same contents
that were notified at the same period of
time considering that they are caused by
the same reason.