is reset.
For a management file to set the power supply interlocking function, use CR and
■
LF, or LF as linefeed code.
For a management file to set the power supply interlocking function, you need to
■
specify the MAC address regardless of the node type. Otherwise, the following
error occurs when you execute the setremotepwrmgmt(8) command.
[Example]
XSCF> setremotepwrmgmt -c config -u guest ftp://xx.xx.xx.xx/rpmgroup.csv
Password:
Download successful: 213Byte at 2103.000KB/s
Checking file...
The definition of [MACAddress] in [ftp://xx.xx.xx.xx/rpmgroup.csv] is invalid.
XSCF>
You need to set the MAC address regardless of the node type of the I/O node,
master host node, host node, or remote power supply control unit. This is required
though the MAC addresses of some nodes are not set and left "blank" in "Chapter
3 Examples of Power Supply Interlocking Configuration" in the Fujitsu M10/
SPARC M10 Systems RCIL User Guide.
Other notes and restrictions
Notes
When the mode switch on the operation panel is set to Service mode, the power
■
cannot be turned on by using the power switch on the operation panel. To turn on
the power using the power switch on the operation panel, set the mode switch on
the operation panel to the Locked mode position.
To add the 64 GB memory, apply XCP 2090 or later.
■
[SPARC M10-1/M10-4/M10-4S]
■
The maximum number of users who can concurrently connect to the XSCF via
Telnet and SSH is as follows:
- M10-1: 20 users
- M10-4: 40 users
- M10-4S (without crossbar box): 40 users
- M10-4S (with crossbar box): 70 users
If the maximum allowable number of users is exceeded, access is denied.
XSCF-LAN is compliant with auto-negotiation. If you connect XSCF-LAN to a
■
network device that is fixed to full-duplex mode, the XSCF-LAN communicates in
half-duplex mode according to the IEEE 802.3 protocol. This may slow down the
speed of network communication or cause communication error. Be sure to set
auto-negotiation for network devices to which you connect XSCF-LAN.
Settings made by the setdualpowerfeed(8) command are immediately applied.
■
Chapter 2 XCP 2240-Related Information