Mitsubishi Electric Q81BD-J61BT11 User Manual page 275

Network interface board melsec cc-link system master/local interface board
Table of Contents

Advertisement

APPENDIX
(Example)
Master station
Address
Station
4000
H
number 1
4001
H
4002
H
4003
H
4004
H
4005
H
4006
H
4007
Station
H
number 2
4008
H
4009
H
400A
H
400B
H
400C
H
400D
H
400E
H
to
41FC
H
41FD
H
41FE
H
41FF
H
App - 13
(8) Ver.2 compatible remote input (RX) and Ver.2 compatible remote
output (RY)
When the remote net ver.2 mode or remote net additional mode is selected, the
number of points indicated below is used.
(a) Master station
station
1) Master station
The input status from the remote I/O station, remote device station
(RX) and local station (RY) is stored.
When 1 station is occupied, 2, 4 or 8 words (32, 64 or 128 points)
are used. The number of used points changes depending on the
expanded cyclic setting and the occupied station count. (refer to
Section 3.2)
2) Local station
Data to be sent to the master station is stored in the remote output
(RY) of the address corresponding to the host station number.
The input status from the remote I/O station, remote device station
(RX) and other local station is stored.
When 1 station is occupied, 2, 4 or 8 words (32, 64 or 128 points)
are used. The number of used points changes depending on the
expanded cyclic setting and the occupied station count. (refer to
Section 3.2)
... The last two bits cannot be used for communication between the master
(Station number 1: Occupies 1 station,
Remote input (RX)
RX F to RX 0
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX 5F to RX 50
RX 6F to RX 60
RX 7F to RX 70
RX 8F to RX 80
RX 9F to RX 90
RX AF to RX A0
RX BF to RX B0
RX CF to RX C0
RX DF to RX D0
RX ED to RX E0
to
RX1FCF to RX1FC0
RX1FDF to RX1FD0
RX1FEF to RX1FE0
RX1FFF to RX1FF0
remote I/O station/remote device station/local
station and the local station.
(In the example below, RYEE and RYEF cannot be used.)
Remote I/O station
Remote I/O station point setting:
16-point setting)
X0F
to
X00
MELSEC
Local station
(Station number 2: Occupies 4 stations,
Expanded cyclic setting: double)
Remote output (RY)
Address
4200
RY F to RY 0
4201
RY 1F to RY 10
4202
RY 2F to RY 20
4203
RY 3F to RY 30
4204
RY 4F to RY 40
4205
RY 5F to RY 50
4206
RY 6F to RY 60
4207
RY 7F to RY 70
4208
RY 8F to RY 80
4209
RY 9F to RY 90
420A
RY AF to RY A0
420B
RY BF to RY B0
420C
RY CF to RY C0
420D
RY DF to RY D0
420E
RY ED to RY E0
to
RY1FCF to RY1FC0
43FC
RY1FDF to RY1FD0
43FD
RY1FEF to RY1FE0
43FE
RY1FFF to RY1FF0
43FF
Station
H
number 1
H
H
H
H
H
H
Station
H
number 2
H
H
H
H
H
H
H
to
H
H
H
H
App - 13