Mitsubishi Electric Q81BD-J61BT11 User Manual page 218

Network interface board melsec cc-link system master/local interface board
Table of Contents

Advertisement

14 COMMUNICATION BETWEEN THE MASTER STATION AND
INTELLIGENT DEVICE STATION (AJ65BT-D75P2-S3)
User Program
2) Reads out the initial data processing request flag
(RX78).
3) With the initial data processing request flag (RX78)
ON, turns ON the initial data processing complete
flag (RY78).
6) Reads out the initial data processing request flag
(RX78).
7) With the initial data processing request flag (RX78)
OFF, turns OFF the initial data processing
complete flag (RY78).
9) Turn ON the initial data setting request flag
(RY79).
12) Reads out the initial data setting complete flag
(RX79).
13) With the initial data setting complete flag (RX79)
ON, turns OFF the initial data setting request flag
(RY79).
16) Reads out the initial data setting complete flag
(RX79).
18) Reads out the remote station READY flag (RX7B).
14 - 6
CC-Link Ver.2 Board
1) When the AJ65BT-D75P2-S3 is turned ON or
reset by the reset switch, the initial data
processing request flag (RX78) is turned ON.
4) Turns ON the initial data processing complete
flag (RY78) of the AJ65BT-D75P2-S3.
5) The AJ65BT-D75P2-S3 turns OFF the initial data
processing request flag (RX78).
8) Turns OFF the initial data processing complete
flag (RY78) of the AJ65BT-D75P2-S3.
10) Turn ON the initial data setting request flag
(RY79) of the AJ65BT-D75P2-S3.
11) The AJ65BT-D75P2-S3 turns ON the initial data
setting complete flag (RX79).
14) Turns OFF the initial data setting request flag
(RY79) of the AJ65BT-D75P2-S3.
15) The AJ65BT-D75P2-S3 turns OFF the initial data
setting complete flag (RX79).
17) The AJ65BT-D75P2-S3 turns ON the remote
station READY flag (RX7B).
MELSEC
14 - 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q80bd-j61bt11n

Table of Contents