Mitsubishi Electric Q81BD-J61BT11 User Manual page 282

Network interface board melsec cc-link system master/local interface board
Table of Contents

Advertisement

APPENDIX
Number
Name
Input data status of
SB0065
host data link faulty
(5E6
, b5)
H
station
SB0066
(5E6
, b6)
H
Number of host
occupied stations
SB0067
(5E6
, b7)
H
SB006A
Switch setting status
(5E6
, b10)
H
SB006D
Parameter setting
(5E6
, b13)
status
H
SB006E
Host station
(5E6
, b14)
operation status
H
SB0070
Master station
(5E7
, b0)
information
H
SB0071
Standby master
(5E7
, b1)
station information
H
SB0072
Scan mode setting
(5E7
, b2)
information
H
Operation
SB0073
specification when
(5E7
, b3)
H
CPU is down status
SB0074
Reserved station
(5E7
, b4)
specified status
H
SB0075
Error invalid station
(5E7
, b5)
specified status
H
Temporary error
SB0076
invalid station setting
(5E7
, b6)
H
information
SB0077
Parameter receive
(5E7
, b7)
status
H
Master station return
SB0079
specification
(5E7
, b9)
H
information
Host master/standby
SB007B
master operation
(5E7
, b11)
H
status
App - 20
Description
Indicates the input status setting from a data link faulty station of
the host.
OFF: Clear
ON : Hold
Indicates the setting status of host occupied stations.
Number of occupied station
1 station
2 stations
3 stations
4 stations
Indicates the setting status of the host.
OFF: Normal
ON : Setting error exists (the error code is stored in SW006A)
Indicates the parameter setting status.
OFF: Normal
ON : Setting error exists (the error code is stored in SW0068)
Indicates the host data link operation status.
OFF: Being executed
ON : Not executed
Indicates the data link status.
OFF: Data link control by the master station
ON : Data link control by the standby master station
Indicates whether or not a standby master station is present.
OFF: Not present
ON : Present
Indicates the scan mode setting information.
OFF: Asynchronous mode
ON : Synchronous mode
Indicates the operation specification status using a parameter
when the CPU is down.
OFF: Stop
ON : Continue
Indicates the reserved station specification status using a
parameter.
OFF: No specification
ON : Specification exists (information is stored in SW0074 to
SW0077)
Indicates the error invalid station specification status using a
parameter.
OFF: No specification
ON : Specification exists (information is stored in SW0078 to
SW007B)
Indicates whether there is a temporary error invalid station setting.
OFF: No setting
ON : Setting exists (information is stored in SW007C to
SW007F)
Indicates the parameter receive status from the master station.
OFF: Reception complete
ON : Reception not complete
Indicates whether the "Type" setting of the host operates is set to
"Master station" or "Master station (Duplex function)."
OFF: Master station
ON : Master station (Duplex function)
Indicates whether the host operates as the master or standby
master station.
OFF: Operates as the master station (controlling data link)
ON : Operates as the standby master station (standby)
SB0066
SB0067
OFF
OFF
OFF
ON
ON
ON
ON
OFF
MELSEC
Availability
( : Available,
: Not available)
Online
Offline
Master
Local
station
station
App - 20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q80bd-j61bt11n

Table of Contents