Adding 2U12 storage shelves to an operational NetBackup 5230 Appliance
Align the two latches at the back of the air duct (A) behind the fans. Press
the latches in to secure them in the tabs.
Lower the front edge of the air duct to engage the two side tabs (B).
12
Replace the chassis cover as follows.
Align the cover with the edge along the top of the chassis.
Place the cover on the chassis so that there is about 1.5 inches of overhang.
Use the blue tabs (1) to slide the cover forward until the cover slides into
place.
Insert the four screws and secure.
13
Reinstall the appliance into the rack as needed.
Toward the rear of the chassis, locate the levers in the extensions on both
sides of the appliance.
Push up and hold the levers to release the extension locking mechanism.
Slide the appliance into the rack. Do not force the appliance into the rack.
If you disconnected the data cables, reconnect them according to the labels
you placed on them earlier.