VERITAS NetBackup 5230 Hardware Installation Manual page 86

Hide thumbs Also See for NetBackup 5230:
Table of Contents

Advertisement

Adding 2U12 storage shelves to an operational NetBackup 5230 Appliance
To prepare the NetBackup 5230 appliance for the installation of the hardware
1
Verify that the appliance is turned off. Refer to this section as needed.
See
"Shutting down the appliance"
2
Slide the NetBackup 5230 appliance forward on the rails to the full extension.
Caution: The unit weighs up to 65 lbs (29.5 kg). Make sure that sliding it forward
does not destabilize the rack.
3
Use these steps if it is necessary to remove the appliance from the rack.
Label and disconnect all cables, including the power cords, from the rear
panel of the appliance.
Warning: If the cables are reconnected to the wrong ports, data can be
corrupted or lost when the appliance is turned on.
Loosen the two front screws that secure the appliance in the rack and
remove the appliance from the rack cabinet.
Place the unit on a grounded, ESD protective surface.
4
Do the following to remove the chassis cover:
Put on an ESD-compliant wrist strap or take other ESD-protective measures.
Remove the four screws (1) from the top of the chassis cover as shown in
the figure.
Press the blue thumb grips (2) to release the locks and slide the cover back
0.5 inches (1.27 cm).
Preparing the appliance to install the additional hardware
on page 85.
86

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents