You can change the boot priority using the Boot Device Priority screen available in the
Note -
Boot menu of the BIOS Setup Utility.
1. NET 0
2. NET 1
3. NET 2
Ethernet Port Device Naming
The device naming for the Ethernet interface is reported differently by different interfaces
and operating systems. The following table shows the BIOS (physical) and operating system
(logical) naming convention for the interface. This naming convention might vary depending on
the conventions of your operating system and which devices are installed in the server.
Naming used by the interfaces might vary from that listed below depending on which
Note -
devices are installed in the system.
Port
Solaris
Net 0
igb0
Net 1
igb1
Net 2
igb2
For Windows, port names like Ethernet, Ethernet 2, and Ethernet 3 are used by default.
Note -
However, actual port naming is based on the order of enumeration, typically during operating
system installation. Additionally, Windows allows you to rename the ports to meet application-
specific needs.

Back Panel Pinhole Switches

This section shows the location of the back panel pinhole switches.
Assign Serial Port Output Using the Oracle ILOM Web Interface
Linux 6
Linux 7
eth0
enp1
eth1
enp2
eth2
enp3
Windows (example default
names, see note below)
Ethernet
Ethernet 2
Ethernet 3
Troubleshooting and Diagnostics
45