Server Fan Status Indicators - Oracle X7-2 Service Manual

Hide thumbs Also See for X7-2:
Table of Contents

Advertisement

Troubleshoot Hardware Faults Using the Oracle ILOM Web Interface
Status Indicator
Name
SP OK
Top Fan
Back Power
Supply Fault
System Over
Temperature
Warning
DO NOT
SERVICE

Server Fan Status Indicators

Each fan module has one status indicator (LED). The LEDs are located on the chassis mid-
wall adjacent to and aligned with the fan modules and are visible when the server top cover is
removed.
30
Oracle Server X7-2 Service Manual • October 2017
Icon
Color
Green
Amber
Amber
Amber
White
State and Meaning
host is booting the operating system (OS), or the
server host is running the OS.
Indicates the state of the service processor.
■ OFF – Service processor (SP) is not running.
■ SLOW BLINK – SP is booting.
■ STEADY ON – SP is fully operational.
Indicates that one or more of the internal fan modules
failed.
■ OFF – Indicates steady state; no service is required.
■ STEADY ON – Indicates service required.
Indicates that one of the server power supplies failed.
■ OFF – Indicates steady state; no service is required.
■ STEADY ON – Indicates service required; service
the power supply.
Indicates a warning for an overtemperature condition.
■ OFF – Normal operation; no service is required.
■ STEADY ON – The system is experiencing an
overtemperature warning condition.
This is a warning indication, not a fatal
Note -
overtemperature. Failure to correct this might result in
the system overheating and shutting down unexpectedly.
Indicates that the system is not ready to service.
■ OFF – Normal operation.
■ STEADY ON – The system is not ready for service.
The DO NOT SERVICE indicator is application
Note -
specific. This indicator is only illuminated on demand by
the Host application.