Oracle X7-2 Service Manual page 60

Hide thumbs Also See for X7-2:
Table of Contents

Advertisement

Extend the Server to the Maintenance Position
Refer to
2.
Verify that no cables will be damaged or will interfere when the server is
extended.
Although the cable management arm (CMA) that is supplied with the server is hinged to
accommodate extending the server, you should ensure that all cables and cords are capable of
extending.
From the front of the server, open and hold the left and right release latch covers
3.
in the open position [1].
When in an open position, the release latch covers engage the slide-rail release latches [1].
Caution -
4.
While the release latch covers are in the open position, slowly pull the server
forward until the slide-rails latch into a locked position [2].
The server is now in the extended maintenance position.
Related Information
"Disconnect Cables From the Server" on page 58
60
Oracle Server X7-2 Service Manual • October 2017
"Stabilize the Rack" in Oracle Servers X7-2 and X7-2L Installation
Deploy any rack anti-tilt mechanism before releasing the slide-rail release latches.
Guide.

Advertisement