Monitoring System Components
Component Name (Oracle ILOM CLI Targets)
/SYS/DBP
/SYS/DBP/PRSNT
/SYS/DBP/HDD[0-x]
/SYS/DBP/HDD[0-x]/PRSNT
/SYS/DBP/HDD[0-x]/STATE
/SYS/DBP/HDD[0-x]/SERVICE
/SYS/DBP/HDD[0-x]/OK2RM
/SYS/DBP/HDD[0-x]/NVME
/SYS/DBP/HDD[0-x]/NVME/PRSNT
Related Information
"System Chassis Components" on page 285
■
"Cooling Unit Components" on page 287
■
"Memory Device Components" on page 289
■
"Power Unit Components" on page 289
■
"Processor Components" on page 290
■
"System Motherboard Components" on page 291
■
"System Firmware Components" on page 293
■
"Hard Disk Drive Components" on page 293
■
288
Oracle Server X7-2 Service Manual • October 2017
IPMI Type
Description
FRU
Disk backplane FRU
Discrete sensor
Disk backplane presence
Pseudo
Hard disk drives (HDD)
Discrete sensor
Hard disk drive presence
State sensor
Hard disk drive state
Indicator
Fault-Service Required
LED
Indicator
Hard disk drive OK to
remove
FRU
NVMe drive FRU
Discrete sensor
NVMe device presence
Values (if applicable)
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
01h-FAULT_STATUS
02h-IDENTITY
04h-INSTALLED
20h-SLOT_POWER_OFF
Color: Amber
Location: HDD
Off: Normal
On: HDD was diagnosed as faulty
Color: Blue
Location: HDD
Off: Normal
On: HDD is OK to remove
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT