Oracle X7-2 Service Manual page 117

Hide thumbs Also See for X7-2:
Table of Contents

Advertisement

See
"Take Antistatic Measures" on page
d.
Remove the server top cover.
See
"Remove the Server Top Cover" on page
2.
If there is a PCIe card installed in PCIe slot 3, disconnect any external or internal
cables.
Do not disconnect the SAS cables from the internal host bus adapter card in slot 4 until
Note -
after you have removed the riser from the server.
3.
Open the green-tabbed latch located on the rear of the server chassis next to
PCIe slot 3 to release the rear bracket on the PCIe card [1].
If the riser does not have a PCIe card installed in slot 3, then lift the latch to release the
Note -
PCIe slot 3 filler panel.
4.
To release the riser from the motherboard connector, lift the green-tabbed
release lever on the PCIe riser to the open position [1].
5.
Grasp the riser with both hands and remove it from the server [2].
6.
Disconnect the M.2 SATA cable between the PCIe riser and motherboard SATA
connector.
Disconnect the SAS cables from the internal HBA card installed in PCIe slot 4.
7.
8.
Disconnect the super capacitor cable from the internal HBA card in slot 4.
Remove the PCIe Riser From PCIe Slots 3 and 4
61.
62.
Servicing PCIe Risers (CRU)