Monitoring System Components
Component Name (Oracle ILOM CLI
Targets)
/SYS/MB/T_OUT_SLOT[1-3]
/SYS/MB/T_IN_SLOT[1-3]
/SYS/SP
/SYS/SP/OK
/SYS/SP/NET[0-1]
/SYS/MB/RISER3
/SYS/MB/RISER3/PRSNT
/SYS/MB/RISER3/SSD[0-1]
/SYS/MB/RISER3/SSD[0-1]/PRSNT
/SYS/MB/RISER3/SSD[0-1]/STATE
Related Information
"System Chassis Components" on page 285
■
"Cooling Unit Components" on page 287
■
"Disk Backplane Components" on page 287
■
"Memory Device Components" on page 289
■
"Power Unit Components" on page 289
■
"Processor Components" on page 290
■
"System Firmware Components" on page 293
■
292
Oracle Server X7-2 Service Manual • October 2017
IPMI Type
Description
Threshold sensor
Cooling zone chassis exhaust
temperature, located behind the
specified PCIe slots
■ Slot 1 – PCIe slot 1
■ Slot 2 – PCIe slot 2
■ Slot 3 – PCIe slot 3
Threshold sensor
Cooling zone chassis inlet
temperature, located in front of the
specified PCIe slots
■ Slot 1 – PCIe slot 1
■ Slot 2 – PCIe slot 2
■ Slot 3 – PCIe slot 3
FRU
Service processor FRU
Indicator
SP OK LED
FRU
SP Ethernet FRU
FRU
M.2 SSD riser
Discrete sensor
M.2 riser presence
FRU
Internal M.2 SSD drives
Discrete sensor
M.2 SSD drive presence
State sensor
M.2 SSD drive state sensor
Values (if applicable)
Degrees Celsius
Degrees Celsius
Color: Green
Location: Front panel
On: SP is operating.
Off: SP requires service.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
04h-INSTALLED
20h-SLOT_POWER_OFF