Oracle X7-2 Service Manual page 156

Hide thumbs Also See for X7-2:
Table of Contents

Advertisement

Install the Disk Backplane
2.
Using a Torx T10 screwdriver, tighten the three storage drive backplane captive
screws clockwise until the disk backplane is secure [2].
3.
Reconnect the disk backplane power cable to the disk backplane [3].
4.
Reconnect the disk backplane data cable and temperature sensor cable to the
disk backplane [4].
5.
Reconnect the SAS cables or the NVMe cables (if present) to the disk backplane
[5].
6.
Reinstall the super capacitor by pressing down on the capacitor to secure it to
the reclosable fastener in the chassis.
7.
Reinstall all of the storage drives into the server.
See
"Install a Storage Drive" on page
8.
Return the server to operation.
a.
Install the server top cover.
See
Return the server to the normal rack position.
b.
See
c.
Reconnect the data cables to the server and reconnect the power cords to
the server power supplies.
See
d.
Power on the server.
See
Verify that the System OK status indicator is steady on.
Related Information
"Remove the Disk Backplane" on page 151
156
Oracle Server X7-2 Service Manual • October 2017
"Install the Server Top Cover" on page 210
"Return the Server to the Normal Rack Position" on page
"Reconnect Data Cables and Power Cords" on page
"Power On the Server" on page
70.
214.
214.
212.

Advertisement

Table of Contents
loading

Table of Contents