Outside Line Types; Transmission, Network, And Control Specifications; Transmission - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 7.0
5.4
5.5
2 - 22
Recommended Long Term Humidity: 10 ~ 90% RH
CD-4LCA
Blades -
PZ-4COTE
,
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature: -20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 20 ~ 90% RH
Door Box
Operating Temperature: -20
Operating Humidity: 20 ~ 80% (non-condensing)
SV8100 Power Supply –
Operating Temperature: 0
Recommended Long Term Temperature: -40
Operating Humidity: 20 ~ 95% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 95% RH

Outside Line Types

The following outside lines can be used with the UNIVERGE SV8100 system.
4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
Digital Trunk T1/FT1 (Loop Start, Tie Line (E&M), or DID Signaling)
ISDN-BRI Trunks
ISDN-PRI Trunks
VoIP Trunks (Internet Protocols)

Transmission, Network, and Control Specifications

5.5.1

Transmission

Data Length:
From Multiline Terminal to CD-8DLCA: 23 bits
From CD-8DLCA to Multiline Terminal: 23 bits
Data Transmission Rates:
Between CD-8DLCA and Multiline Terminal: 184K bps (voice and
signaling)
Scanning Time for each Multiline Terminal: 32 ms.
PZ-4LCA
CD-8LCA
,
,
CD-PRTA
o
C ~ 60
MPS7101
o
C ~ +40
UNIVERGE SV8100
PZ-8LCE
CD-4COTA
,
,
o
C
o
C
o
o
C ~ 75
C
SV8100 System Specifications
,