External Recording System/External Ringer; External Recording System Or External Ringer - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
E
S
7
XTERNAL
ECTION
7.1
System Hardware Manual
R
ECORDING

External Recording System or External Ringer

The PGD(2)-U10 ADP allows the connection of an external recording system
or external ringer. With a customer-provided tape recorder, when an extension
user dials the ACI analog port extension number, they can automatically start
the recorder and activate the record function. When the user hangs up, the
recording stops and the tape recorder turns off. For tape recording, connect
the tape recorder AUX input jack to the PGD(2)-U10 ADP jack. Connect the
recorder control leads (if available) to the CTL (control relay) jack. By using
Department Calling, you can arrange multiple tape recorders into a pool.
When an extension user dials the Department Group pilot number, they reach
the first available tape recorder in the pool.
The relays in the PGD(2)-U10 ADP can optionally control customer-provided
external ringers (loud bells) and buzzers. When an extension user dials the
ACI analog port extension number, the associated PGD(2)-U10 ADP relay
closes and activates the ringer. You could use this capability to control an
emergency buzzer for a noisy machine shop floor, for example. In addition, if
programmed for ringing, an incoming trunk call can activate the ringer/buzzer.
The relay closes when the Door Box/external
page zone is called. The maximum applied
voltage is 24vDC at .5A for each contact.