Parameters For Full-Closed - Panasonic minas a4 series Instruction Manual

Ac servo motor and driver
Hide thumbs Also See for minas a4 series:
Table of Contents

Advertisement

Parameter Setup
PrNo.
Title
72
Setup of
over-load level
73
Setup of
over-speed level
Parameters for Full-Closed Control
PrNo.
Title
78
Numerator of
*
external scale
division
79
Multiplier of
*
numerator of
external scale
division
7A
Denominator of
*
external scale
division
7B
Setup of hybrid
*
deviation excess
7C
Reversal of
*
direction of
external scale
<Notes>
• For parameters which No. have a suffix of "*", changed contents will be validated when you turn on the
control power.
224
Setup
Unit
range
0 to 500
%
• You can set up the over-load level. The overload level becomes 115 [%]
<0>
by setting up this to 0.
• Use this with 0 setup in normal operation. Set up other value only when
you need to lower the over-load level.
• The setup value of this parameter is limited by 115[%] of the motor rating.
0 to 20000
r/min
• You can set up the over-speed level. The over-speed level becomes 1.2
times of the motor max. speed by setting up this to 0.
<0>
• Use this with 0 setup in normal operation. Set up other value only when
you need to lower the over-speed level.
• The setup value of this parameter is limited by 1.2 times of the motor
max. speed.
<Caution>
The detection error against the setup value is ±3 [r/min] in case of the 7-wire
absolute encoder, and ±36 [r/min] in case of the 5-wire incremental encoder.
Setup
Unit
range
0 to 32767
You can setup the ratio between the encoder resolution and the external
scale resolution at full-closed control.
<0>
Encoder resolution per one motor revolution
External scale resolution per one motor revolution
• Pr78= <0> (default)
0 to 17
Numerator equals to encoder resolution, and you can setup
<0>
the external scale resolution per one motor revolution with Pr7A.
• Pr78 ≠ 0,
Setup the ratio between the external scale resolution and the encoder
resolution per one motor revolution according to the above formula.
1 to 32767
<Caution>
<10000>
• Upper limit of numerator value after calculation is 131072. Setup
exceeding this value will be invalidated, and 131702 will be the actual
numerator.
1 to 10000
16 x
• You can setup the permissible gap (hybrid deviation) between the
<100>
external
present motor position and the present external scale position.
scale
• The driver will trip with Err25 (Hybrid deviation excess protection) when
pulse
the deviation is generated which exceeds the permissible gap.
0 to 1
You can set up the logic of the absolute data of the external scale.
<0>
Setup value
<Caution>
When you use the linear scale by other manufacture than Mitutoyo,
position data will be kept as it is with the setup of 0, and it will become as
a reversed signed position data with the setup of 1.
Function/Content
Function/Content
Serial data will increase when the detection head travels
0
to the right viewed from the mounting side. (+ count)
Serial data will decrease when the detection head travels
1
to the right viewed from the mounting side. (– count)
Standard default : < >
Standard default : < >
Pr79
Pr78 X 2
=
Pr7A
Content