Panasonic minas a4 series Instruction Manual page 323

Ac servo motor and driver
Hide thumbs Also See for minas a4 series:
Table of Contents

Advertisement

Reactor
Fig.1
X Y Z
NP
R S T
6-1
A
4-H
(Mounting pitch)
(Mounting pitch)
B
Fig.2
2-1
A
4-H
(Mounting pitch)
(Mounting pitch)
B
Harmonic restraint
On September, 1994, "Guidelines for harmonic restraint on heavy consumers who receive power through
high voltage system or extra high voltage system" and "Guidelines for harmonic restraint on household
electrical appliances and general-purpose articles" established by the Agency for Natural Resources and
Energy of the Ministry of Economy, Trade and Industry (the ex-Ministry of International Trade and Industry).
According to those guidelines, the Japan Electrical Manufacturers' Association (JEMA) have prepared tech-
nical documents (procedure to execute harmonic restraint: JEM-TR 198, JEM-TR 199 and JEM-TR 201)
and have been requesting the users to understand the restraint and to cooperate with us. On January, 2004,
it has been decided to exclude the general-purpose inverter and servo driver from the "Guidelines for har-
monic restraint on household electrical appliances and general-purpose articles". After that, the "Guidelines
for harmonic restraint on household electrical appliances and general-purpose articles" was abolished on
September 6, 2004.
We are pleased to inform you that the procedure to execute the harmonic restraint on general-purpose
inverter and servo driver was modified as follows.
1.All types of the general-purpose inverters and servo drivers used by specific users are under the control of
the "Guidelines for harmonic restraint on heavy consumers who receive power through high voltage sys-
tem or extra high voltage system". The users who are required to apply the guidelines must calculate the
equivalent capacity and harmonic current according to the guidelines and must take appropriate counter-
measures if the harmonic current exceeds a limit value specified in a contract demand. (Refer to JEM-TR
210 and JEM-TR 225.)
2.The "Guidelines for harmonic restraint on household electrical appliances and general-purpose articles"
was abolished on September 6, 2004. However, based on conventional guidelines, JEMA applies the
technical documents JEM-TR 226 and JEM-TR 227 to any users who do not fit into the "Guidelines for
harmonic restraint on heavy consumers who receive power through high voltage system or extra high
voltage system" from a perspective on enlightenment on general harmonic restraint. The purpose of these
guidelines is the execution of harmonic restraint at every device by a user as usual to the utmost extent.
Part No.
A
DV0P220
65
DV0P221
60
DV0P222
60
DV0P223
60
DV0P224
60
E
DV0P225
60
DV0P226
55
DV0P227
55
DV0P228
55
DV0P229
55
Motor
Power
F
series
supply
G
MSMD
Single
MQMA
phase,
MSMD
100V
MQMA
E
MSMD
MQMA
MAMA
Single
MFMA
phase,
MHMA
200V
MSMD
F
MQMA
MAMA
G
MAMA
MFMA
3-phase,
MHMA
200V
MSMD
MAMA
B
C
D
E
F
125
83
118
145
70
150
113
137
120
60
150
113
137
130
70
150
113
137
140
79
150
113
137
145
84
150
113
137
160
100
80
68
90
90
41
80
68
90
90
41
80
68
90
95
46
80
68
90
105
56
Rated
Part No.
output
50W to 100W
DV0P227
100W
200W to 400W
DV0P228
50W to 200W
100W to 200W
DV0P220
400W
500W
400W to 750W
400W
DV0P221
400W to 750W
400W
DV0P220
500W
750W
DV0P221
[Supplement]
Inductance
G
H
I
(mH)
85
7(w) x 12(L)
M4
6.81
75
7(w) x 12(L)
M4
4.02
95
7(w) x 12(L)
M4
95
7(w) x 12(L)
M4
1.39
100
7(w) x 12(L)
M4
0.848
115
7(w) x 12(L)
M5
0.557
55
ø7.0
M4
6.81
55
ø7.0
M4
4.02
60
ø7.0
M4
70
ø7.0
M4
1.39
Motor
Power
Rated
series
supply
output
MGMA
900W
MSMA
1.0kW
MDMA
1.5kW
MHMA
MFMA
1.5kW
MSMA
MDMA
3-phase,
2.0kW
MHMA
200V
MGMA
MFMA
2.5kW
MSMA
MDMA
3.0kW
MHMA
MGMA
MSMA
MDMA
4.0kW
MHMA
Rated
current
(A)
3
5
2
8
11
16
25
3
5
2
8
11
Part No.
DV0P222
DV0P223
DV0P224
DV0P225
321

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents