Panasonic minas a4 series Instruction Manual page 215

Ac servo motor and driver
Hide thumbs Also See for minas a4 series:
Table of Contents

Advertisement

PrNo.
Title
22
Selection of
machine stiffness
at real-time
auto-gain tuning
23
Setup of adaptive
filter mode
24
Selection of
damping filter
switching
25
Setup of an action
at normal mode
auto-gain tuning
26
Setup of software
limit
28
2nd notch
frequency
29
Selection of
2nd notch width
2A
Selection of
2nd notch depth
<Notes>
• Parameters which default values have a suffix of "*" will be automatically set up during real time auto-gain
tuning. When you change manually, invalidate the real-time auto-gain tuning first then set, referring to
P.239, "Release of Automatic Gain Adjusting Function" of Adjustment.
[Connection and Setup of Full-closed Control]
Setup
Unit
range
You can set up the machine stiffness in 16 steps while the real-time auto-
0 to 15
gain tuning is valid.
A to C-frame:
<4>
D to F-frame:
<1>
<Caution>
When you change the setup value rapidly, the gain changes rapidly as
well, and this may give impact to the machine.
gradually watching the movement of the machine.
You can set up the action of the adaptive filter.
0 to 2
0 : Invalid
<1>
1 : Valid
2 : Hold (holds the adaptive filter frequency when this setup is changed to 2.)
<Caution>
When you set up the adaptive filter to invalid, the adaptive filter frequency
of Pr2F will be reset to 0. The adaptive filter is always invalid at the
torque control mode.
0 to 2
You can select the switching method when you use the damping filter.
<0>
0 : No switching (both of 1st and 2nd are valid.)
1 : You can select either 1st or 2nd with damping control switching input
(VS-SEL).
2 : You can switch with the position command direction.
0 to 7
You can set up the action pattern at the normal mode auto-gain tuning.
<0>
Setup value
<0>
1
2
3
4
5
6
7
e.g.) When the setup is 0, the motor turns 2 revolutions to CCW and 2
revolutions to CW.
You can set up the movable range of the motor against the position
0 to 1000
0.1
command input range. When the motor movement exceeds the setup
<10>
revolution
value, software limit protection of Pr34 will be triggered. This parameter is
invalid with setup value of 0.
100 to 1500
Hz
You can set up the 2nd notch width of the resonance suppressing filter in
<1500>
5 steps. The notch filter function is invalidated by setting up this parame-
ter to "1500".
0 to 4
You can set up the notch width of 2nd resonance suppressing filter in 5
<2>
steps. Higher the setup, larger the notch width you can obtain.
Use with default setup in normal operation.
0 to 99
You can set up the 2nd notch depth of the resonance suppressing filter. Higher
<0>
the setup, shallower the notch depth and smaller the phase delay you can obtain.
Function/Content
low
machine stiffness
low
servo gain
Pr22
0, 1- - - - - - - - - - - - 14, 15
low
response
when VS-SEL is opened, 1st damping filter selection (Pr2B, 2C)
when VS-SEL is close, 2nd damping filter selection (Pr2D, 2E)
CCW : 1st damping filter selection (Pr2B, 2C).
CW : 2nd damping filter selection (Pr2D, 2E).
Number of revolution
2 [revolution]
1 [revolution]
Standard default : < >
high
high
high
Increase the setup
Rotational direction
CCW
CW
CW
CCW
CCW
CCW
CW
CW
CCW
CW
CW
CCW
CCW
CCW
CW
CW
213