Panasonic minas a4 series Instruction Manual page 349

Ac servo motor and driver
Hide thumbs Also See for minas a4 series:
Table of Contents

Advertisement

MDMA series
(3.0kW to 5.0kW)
• MDMA302 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
50
(42.9)
Peak running range
25
(14.3)
Continuous running range
0
1000
2000
3000
speed [r/min]
• MDMA502 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
(71.4)
70
Peak running range
35
(23.8)
Continuous running range
0
1000
2000
3000
speed [r/min]
MFMA series
(400W to 4.5kW)
• MFMA042 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
(5.3)
5
Peak running range
2.5
(1.9)
Continuous running range
0
1000
2000
3000
speed [r/min]
• MFMA252 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
(30.4)
30
Peak running range
15
(11.8)
Continuous running range
0
1000
2000
3000
speed [r/min]
* These are subject to change. Contact us when you use these values for your machine design.
With oil seal
* Continuous torque vs.
ambient temp.
100
50
40
0
10
20
30
ambient temp. [ ˚C]
without
* Continuous torque vs.
brake
ambient temp.
with
brake
100
90
85
50
0
10
20
30
40
ambient temp. [ ˚C]
With oil seal
* Continuous torque vs.
ambient temp.
100
50
0
10
20
30
40
ambient temp. [ ˚C]
* Continuous torque vs.
ambient temp.
100
50
0
10
20
30
40
ambient temp. [ ˚C]
• MDMA402 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
(56.4)
50
Peak running range
25
(18.8)
Continuous running range
0
1000
2000
3000
speed [r/min]
• MFMA152 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
(21.5)
20
Peak running range
10
(7.15)
Continuous running range
0
1000
2000
3000
speed [r/min]
• MFMA452 * 1 *
Input voltage to driver: AC200V
(Dotted line represents torque at 10% less voltage.)
torque
[N
m]
(54.9)
50
Peak running range
25
(21.5)
Continuous running range
0
1000
2000
3000
speed [r/min]
• When you lower the torque limit setup (Pr5E and 5F),
running range at high speed might be lowered as well.
torque
Continuous running range
speed
[Supplement]
* Continuous torque vs.
without
brake
ambient temp.
with
brake
100
85
70
50
0
10
20
30
40
ambient temp. [ ˚C]
* Continuous torque vs.
ambient temp.
100
50
0
10
20
30
40
ambient temp. [ ˚C]
* Continuous torque vs.
ambient temp.
100
50
0
10
20
30
40
ambient temp. [ ˚C]
Running range (Torque limit setup : 300%)
Running range (Torque limit setup : 200%)
Running range (Torque limit setup : 100%)
347