TABLE X-XIV. OIL TEMPERATURE INDICATORS
Trouble
Cause
Remedy
Instrument fails to
Broken or damaged
Check engine unit and
show any reading.
capillary. Wiring
wiring to instrument.
open.
Excessive error.
Improper calibration
Replace instrument.
adjustment.
Pointer fails to
Broken or damaged
Check engine unit and
move as engine is
capillary or open
wiring.
warmed up.
wiring.
Dull or discolored
Age.
Replace instrument.
marking.