High Oil Temperature; Electrical Failures - Piper ARCHER III Pilot Operating Handbook

Hide thumbs Also See for ARCHER III:
Table of Contents

Advertisement

PA-28-181, ARCHER III

HIGH OIL TEMPERATURE

Land at nearest airport and investigate the problem.
Prepare for power off landing.

ELECTRICAL FAILURES

Anytime the bus voltage is below 25 Vdc, the Low
Bus Voltage Annunciator will be illuminated.
ALT annunciator light illuminated:
Ammeter........................................................................Check to verify inop. alt.
If ammeter shows zero:
ALT switch.....................................................................................................OFF
Reduce electrical loads to minimum:
ALT circuit breaker......................................................................Check and reset
ALT switch ......................................................................................................ON
If power not restored:
ALT switch.....................................................................................................OFF
If alternator output cannot be restored, reduce electrical loads and land as soon
as practical. Anticipate complete electrical failure. Duration of battery power
will be dependent on electrical load and battery condition prior to failure.
Low Bus Voltage Annunciator will be illuminated.
ISSUED: JULY 12, 1995
EMERGENCY PROCEDURES
NOTE:
NOTE:
SECTION 3
as required
REPORT: VB-1611
3-5

Advertisement