10-2. Window Comparator Mode Setting Function

Either normal mode or window comparator mode can be selected.
If selecting window comparator mode, choose and set the teaching method from among 1-level teaching / 2-level
teaching / 3-level teaching.
Normal mode
Move the Jog switch to select
the desired output mode.
Press the
Jog switch.
The digital display will blink quickly
3 times to confirm the selection.
The unit will shift into teaching mode.
(Go to procedure 2 on p. 9 and 10.)
1-level
teaching
Move the Jog switch to select
the desired teaching method.
Press the
Jog switch.
Move the Jog switch to select
the desired shift level.
Press the
Jog switch.
The digital display will blink quickly
3 times to confirm the selection.
The unit will shift into teaching mode.
(Go to procedure 2 on p. 12.)
Press the MODE
key 5 times.
Move the Jog switch
toward the '
' direction
6 times.
Press the
Jog switch.
Press the
Jog switch.
Window comparator
mode
Press the
Jog switch.
The digital display will blink quickly
3 times to confirm the selection.
2-level
3-level
teaching
teaching
Press the
Jog switch.
The digital display will blink quickly
3 times to confirm the selection.
The unit will shift into teaching mode.
(Go to procedure 2 on p. 13 and 14.)
1 Press the [MODE key] 5 times to select 'PRO mode'.
2 Move the [Jog switch] toward the '
select 'PRO mode'.
3 Press the [Jog switch] to enter the 'window comparator mode
setting' state.
4 If the [Jog switch] is pressed, the current sensing mode will
be displayed.
5 If the [Jog switch] is pressed, the digital display will start
blinking.
Select the desired 'output mode'.
* The factory setting is 'normal mode'.
6 If selecting normal mode...If the [Jog switch] is pressed, the
If selecting window comparator mode...If the [Jog switch] is pressed, the
7 If the [Jog switch] is moved, the digital display will start
blinking.
Select the desired 'teaching method'.
* The factory setting is '1-level teaching'.
8 If selecting 1-level teaching... If the [Jog switch] is pressed, the unit
If selecting 2-level or 3-level teaching... If the [Jog switch] is pressed, the
9 (If selecting 1-level teaching)...If the [Jog switch] is pressed, the
54
' direction 6 times to
digital display will blink quickly 3
times and the unit will shift into
teaching mode. (Go to procedure
2 on p. 9 and 10.)
digital display will blink quickly
3 times and the unit will enter the
'select teaching method' state.
* Refer to p. 6 for information on
teaching.
will enter the 'shift level' selection
state. Move the [Jog switch] to
select the desired shift level.
* The factory setting for shift level is '100'.
digital display will blink quickly
3 times and the unit will shift into
teaching mode.
(Go to procedure 2 on p. 13 and 14.)
digital display will blink quickly
3 times and the unit will shift into
teaching mode.
(Go to procedure 2 on p. 12.)