Factory Settings; Error Display Indicator Readings - Sunx FX-301 Operation Manual

Pro mode digital fiber sensor
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

3-2. Factory Settings

Factory settings for the FX-301 /302/303 are indicated below:
If the unit is reset using the '9-5 Setting Reset Function' from 'PRO5 Mode' on p.52, the resulting settings will be
those indicated below:
NAVI mode
Item
Threshold value
Light state operation
Timer operation
PRO mode
Response time
Timer period
Hysteresis
Stability
Amount of shift during limit teaching
Amount of shift during full-auto teaching
Display
Display orientation
ECO mode
Selection for transmission change to permit/not to permit (FX-301B/G/H and FX-302 only)
Code
0_ADJ
Adjust Lock
Window comparator mode (FX-302 only)
Window comparator hysteresis (FX-302 only)
Notes: 1)This digital display is 10 ms OFF-delay timer.
2)Full-auto teaching can be set only in the FX-301B/G/H.
3)When in window comparator mode, the factory settings for teaching method and shift value are, respectively: '1-level teaching' and '100'.

3-3. Error Display Indicator Readings

In case of errors, attempt the following measures:
Digital display
Error description
The load has short-circuited
and excess current is flowing.
Communication error has
occurred at time of connection.
In case of using functions
(
of PRO4 mode
Item
(Note 2)
(Note 3)
)
Settings
40
L-ON (ON when light is received)
Without timer
Settings
Standard
10 ms
H-02 (standard)
S-02 (standard)
15 %
0 %
Incident light intensity display
OFF
OFF
OFF
0000
OFF
OFF
OFF
IN Hysteresis
Measures
Turn off the power, then check
the load.
Confirm that all amplifier units are
properly connected to each other.
4
Digital display
Digital display
FX-301 , FX-302:
FX-303:
(Note1)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-303Fx-302

Table of Contents