4-6. Output Operation Setting Mode
This mode allows the selection of output operation from either L-ON (Light-ON), or D-ON (Dark-ON).
Output operation
FX-301 , FX-303 or FX-302 normal mode
Output
operation
L-ON
OFF
ON
D-ON
ON
OFF
Incident
light
Threshold value
intensity
The current
setting
The digital display will quickly
blink 3 times to confirm the selection.
FX-302 window comparator mode
Output
operation
L-ON
OFF
ON
OFF
D-ON
ON
OFF
ON
Threshold
Threshold
value 1
value 2
Press the
1 Press the [MODE key] 3 times to select the
MODE key
'output operation setting mode'.
3 times.
2 The current setting will be displayed.
* The factory setting is L-ON (ON when light is received).
Move the
3 If the [Jog switch] is moved, the opposite setting for output
Jog switch.
operation will blink on the display.
Press the
4 If the [Jog switch] is pressed, the digital display will blink quickly
Jog switch.
3 times and the selected output operation will be confirmed.
Press the MODE key
3 times or keep it pressed
5 Press the [MODE key] 3 times or keep it pressed
for 2 sec. or more.
for 2 sec. or more to return to 'RUN mode'
(normal sensing operation).
19
Incident
light
intensity