Pro5 Mode; Pro5 Mode Functions And Settings - Sunx FX-301 Operation Manual

Pro mode digital fiber sensor
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

9

PRO5 Mode

9-1. PRO5 Mode Functions and Settings

PRO5 mode allows the input of direct codes and the setting of the 0-adjust and adjust lock functions.
It also permits the unit to be reset (re-initialized).
Direct Code
FX-301 , FX-302 and FX-303 contain certain encoded basic configuration information that can be set by inputting a
4-digit code.
The functions that may be set using direct coding are: Response time, Hysteresis, L-ON / D-ON, Display setting,
Adjust lock setting function, Timer operation and Timer period.
[FX-301
Code Setting Table]
First digit
Direct
Response
Hysteresis
Check
code
Time
STD
H-02 (standard)
STD
H-03 (large)
STD
H-01 (small)
LONG
H-02 (standard)
LONG
H-03 (large)
LONG
H-01 (small)
FAST
H-02 (standard)
FAST
H-03 (large)
FAST
H-01 (small)
*S-D
H-02 (standard)
[FX-302 Code Setting Table]
First digit
Direct
Response
Hysteresis
Check
code
Time
STD
H-02 (standard)
STD
H-03 (large)
STD
H-01 (small)
LONG
H-02 (standard)
LONG
H-03 (large)
H-01 (small)
LONG
FAST
H-02 (standard)
FAST
H-03 (large)
FAST
H-01 (small)
S-D
H-02 (standard)
S-D
H-03 (large)
S-D
H-01 (small)
Second digit
Direct
L-ON / D-ON
Display
code
L-ON
Incident light intensity
L-ON
%
L-ON
Peak hold
L-ON
Bottom hold
D-ON
Incident light intensity
D-ON
%
D-ON
Peak hold
D-ON
Bottom hold
*S-D (reduced intensity) cannot be set for the
FX-301B/G/H (Blue, Green and Infrared LED types).
Second digit
Direct
L-ON / D-ON
Display
code
L-ON
Incident light intensity
L-ON
%
L-ON
Peak hold
L-ON
Bottom hold
D-ON
Incident light intensity
D-ON
%
D-ON
Peak hold
D-ON
Bottom hold
Third digit
Direct
Adjust
Check
Timer operation
code
lock
ON
NON (without timer)
ON
OFF-delay
ON-delay
ON
ON
ONE-SHOT
NON (without timer)
OFF
OFF
OFF-delay
OFF
ON-delay
OFF
ONE-SHOT
Third digit
Direct
Adjust
Check
Timer operation
code
lock
ON
NON (without timer)
OFF-delay
ON
ON
ON-delay
ONE-SHOT
ON
OFF
NON (without timer)
OFF
OFF-delay
OFF
ON-delay
OFF
ONE-SHOT
ON-delay • OFF-delay
ON
ON-delay • ONE-SHOT
ON
ON-delay • OFF-delay
OFF
ON-delay • ONE-SHOT
OFF
* In the event that the timer operation for ON-delay / OFF-delay or
ON-delay / ONE-SHOT (8~b) are both set using the 3rd digit, then
the timer setting selected by the 4th digit will be common to both timer
operations.
47
Fourth digit
Direct
Timer
Check
Check
code
period
OFF
1 ms
3 ms
5 ms
10 ms
30 ms
50 ms
100 ms
300 ms
500 ms
Fourth digit
Direct
Timer
Check
Check
code
period
OFF
1 ms
3 ms
5 ms
10 ms
30 ms
50 ms
100 ms
300 ms
500 ms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-303Fx-302

Table of Contents