4-5. Threshold Value Fine Adjustment Mode (when using FX-302 window comparator mode)
This mode allows fine adjustment of the 'Threshold value(1_SL, 2_SL)' setting.
Select the desired threshold value
by moving the Jog switch.
When changing
threshold value
to 85.
The digital display will quickly
blink 3 times to verify the value.
Press the
1 Press the [MODE key] twice to select the 'threshold value
MODE key twice.
fine adjustment mode'.
2The lower limit setting '
Press the
3 If the [Jog switch] is pressed, the threshold value for
Jog switch.
'1_SL' is displayed.
If an increased 'threshold value' is desired,
move the [Jog switch] toward the '
If a decreased 'threshold value' is desired,
move the [Jog switch] toward the '
Press the
4 If the [Jog switch] is pressed, the display will blink quickly
Jog switch.
three times and the threshold value for '1_SL' will be set.
5 '
upper limit setting '
Move the
Jog switch.
17
' is displayed.
' is displayed. If the [Jog switch] is moved, then the
' is displayed.
' direction.
' direction.