5-4. Timer Setting Function (FX-302)

Six different timer operations can be selected: Without timer, OFF-delay,
ON-delay, ONE-SHOT, ON-delay / OFF-delay, ON-delay / ONE-SHOT.
The range of available timer is 0.5 to 5 sec.
However, the increments available for timer delays will vary, depending on
the timer period, as shown in the table on the right.
Without timer
OFF-delay
ON-delay
Select the desired timer operation
by moving the Jog switch.
Select the desired time period
by moving the Jog switch.
The digital display will quickly blink 3 times to confirm the setting.
Press the MODE
key 5 times.
Move the Jog switch
once, toward
the '
' direction.
Press the
Jog switch.
Move the Jog switch
once, toward
the '
' direction.
Press the
Jog switch.
ONE-SHOT
ON-delay / OFF-delay ON-delay / ONE-SHOT
Press the
Jog switch.
The di g i t al di s pl a y wi l l qui c kl y bl i n k
Press the
Jog switch.
3 ti m es to confi r m the setti n g.
Select the desired time period
by moving the Jog switch.
Press the
Jog switch.
Press the MODE key 3
times or keep it pressed
for 2 sec. or more.
1 Press the [MODE key] 5 times to select 'PRO mode'.
2 Move the [Jog switch] once toward the '
to select 'PRO1 mode'.
3 Press the [Jog switch] to enter the 'response time change' state.
4 Move the [Jog switch] once toward the '
to enter the 'timer setting' state.
5 If the [Jog switch] is pressed, the current timer
operation will be displayed.
* The factory setting is Without timer.
6 If the [Jog switch] is moved, the digital display will blink.
Select the desired timer operation.
* The factory settings allow timer operation to be switched
using timer operation setting mode, between Without
timer and 10 ms OFF-delay, when in 'NAVI mode'.
When set to '15 ms ON-delay', the selected timer
function can be: Without timer / 15 ms ON-delay.
7 Press the [Jog switch] to enter the 'timer setting selection' state.
* The factory setting is 10 ms.
8 Select the desired timer period by moving the Jog switch.
When using the ON-delay / OFF-delay timer combination or
the ON-delay / ONE-SHOT timer combination, each timer
can be set individually.
* Timer period will be switched to the values set by timer
operations, unless 'Without timer' is chosen.
Example: If the OFF-delay timer has been initially set to 500 ms
and then the ON-delay timer is also set to 500 ms,
then '
' is displayed.In addition, when the
ON-delay timer is set to 4.5 sec., then '
be displayed.
9 If the [Jog switch] is pressed, the digital display will quickly
blink 3 times, confirming the setting.
0 Press the [MODE key] 3 times or keep it pressed
for 2 sec. or more to return to 'RUN mode'
(normal sensing operation).
26
Timer period
Delay increments
0.5 ms,1 to 30 ms
1 ms increments
30 to 100 ms
5 ms increments
100 to 500 ms
10 ms increments
500 ms to 1 sec.
50 ms increments
1 sec. to 5 sec.
0.5 sec. increments
' direction,