Pro1 Mode; Pro1 Mode Functions And Settings - Sunx FX-301 Operation Manual

Pro mode digital fiber sensor
Hide thumbs Also See for FX-301:
Table of Contents

Advertisement

5

PRO1 Mode

5-1. PRO1 Mode Functions and Settings

PRO1 mode is used mainly for configuring the details of basic settings.
: Response Time Change Function
Refer to p.24 for setting procedure
: Timer Setting Function
Refer to p.25~ for setting procedure
The response times for the FX-301
levels: FAST (high-speed), S-D (reduced intensity), STD (standard) and LONG
(long-range). The switching of response times among these four levels will cause
corresponding changes to the sensing range.
The FX-303 has only a single response time of 90 !s.
* The factory setting is STD (standard).
S-D (reduced intensity) cannot be set for the FX-301B/G/H (Blue, Green and Infrared LED types).
Setting
FX-301
(high-speed)
(reduced intensity)
(standard)
(long-range)
(high-speed): when performing sensing of high-speed objects
*
(reduced intensity): Suitable for delicate sensing, such as when the received
lights is saturated due to too short a sensing distance or
when detecting translucent objects, etc.
(standard): standard setting
(long-range): when long sensing range is required
P.25
FX-301
,FX-303
Four different timer operations can be selected; Without timer , OFF-delay ,
ON-delay , ONE-SHOT. The range of available timer delays is 0.5 to 500 ms.
However, the increments available for timer delays will vary, depending on the
timer period on p.22.
* The factory settings allow timer operation to be switched between Without timer
and 10 ms OFF-delay when in 'NAVI mode'.
FX-302
P.26
Six different timer operations can be selected: Without timer, OFF-delay,
ON-delay, ONE-SHOT, ON-delay / OFF-delay, ON-delay / ONE-SHOT.
The range of available timer is 0.5 to 5 sec.
However, the increments available for timer delays will vary, depending on the
timer period on p.22.
* The factory settings allow timer operation to be switched between Without timer
and 10 ms OFF-delay when in 'NAVI mode'.
* OFF-delay : Extends the output signal for a fixed period of time.
This function is useful if the output signal is so short that the connected
device cannot respond.
ON-delay : Neglects short output signals.
As only long signals are extracted, this function is useful for detecting if a
line is clogged, or for sensing only objects taking a long time to travel.
ONE-SHOT : Outputs a fixed width signal upon sensing.
This function is useful when the input specifications of the connected
device require a signal of fixed width. Of course, it is also useful for
extending a short width signal to a desired width.
ON-delay / OFF-delay : The ON-delay and the OFF-delay timer functions can operate
simultaneously.
ON-delay / ONE-SHOT : The ON-delay and the ONE-SHOT timer functions can
operate simultaneously.
21
and FX-302 can be switched among four
Response time
FX-302 Response time
150!s (0.15 ms) or less
300!s (0.3 ms) or less
250!s (0.25 ms) or less
500!s (0.5 ms) or less
2 ms or less
4 ms or less

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-303Fx-302

Table of Contents