2

Diagram of Functions and Settings

2-1. Diagram of Functions and Settings
The amplifier features and settings are generally classified into two main modes; the 'NAVI mode' for items and
settings that are frequently reconfigured, and the 'PRO mode' that contains more detailed settings.
RUN
Run
This indicates normal sensing
operation.
NAVI
mode
PRO
Pro
Allows various detailed settings to be
configured, such as optical communications,
save/load and other settings.
Switches
PRO1
times. (Refer to p.24)
P. 21~
Allows selection of different
PRO2
content to be viewed in the
P. 31~
digital display. (Refer to p.33)
PRO
Loads configuration setting
PRO3
mode
from the data bank.
P. 38~
(Refer to p.39)
Using optical communications, configuration
PRO4
settings from the main unit are copied to connected
P.41~
sub units, in a single step. (Refer to p.42)
* The FX-303 is not
equipped with a PRO4
setting function.
Allows basic configuration information
PRO5
to be set in a single step, by inputting
P.47~
a 4-digit code. (Refer to p.49)
FX-301
FX-303
* Available only in FX-302
Configures window comparator
PRO6
mode and teaching method.
P.53~
(Refer to p.54)
TEACH
The ' t hreshol d val u e' for the FX-301 and FX-303 can be set by
uti l i z i n g ei t her ' 2 -l e vel teachi n g' or ' l i m i t teachi n g' , and the ' t hreshol d
val u e' for the FX-301B/G/H can be set usi n g these and al s o a thi r d
mode cal l e d ' f ul l - auto teachi n g' . When the FX-302 i s i n wi n dow
comparator mode, the ' t hreshol d val u e' can be set by ei t her ' 1 -l e vel
teachi n g' , ' 2 -l e vel teachi n g' or ' 3 -l e vel teachi n g' . (Refer to p.9~)
TIMER
Configures operation of the timer.
(Refer to p.20)
Response Time Change
among
response
Configures timer operation and
timer period. (Refer to p.25~)
Shifts the 'threshold value' by a certain
percentage increment during 'limit teaching'
or 'full-auto teaching'. (Refer to p.29)
Digital Display Setting
Sets the viewing orientation of
the digital display.
(Refer to p.34)
Data Bank Load
Saves configuration setting
into the data bank.
(Refer to p.40)
Copy
Using
configuration settings can be loaded from
data banks, in a single step. (Refer to p.43)
* Available only in FX-301B/G/H, FX-302
Allows all communication changes to be disabled during
the execution of single-step copy, load and save
operations using optical communications. (Refer to p.46.)
Coding
Forces the numerical value for
incident light intensity to '0', on
the digital display. (Refer to p.50)
Window Comparator Mode Setting
Configures
(IN/OUT)
comparator mode. (Refer to p.55)
2
Teaching
ADJ
Allows fine adjustment of the
'threshold value'. (Refer to p.16~)
L/D ON
Timer
Sets output operation either Light-
ON, or Dark-ON. (Refer to p.19)
Timer Setting
Shift
Digital Display Inversion
Data Bank Save
Remote Data Bank Load
optical
communications,
Transmission Change
To Permit/Not to Permit
Zero Adjust
Window Comparator Hysteresis
the
hysteresis
when
in
window
Adjust
L-ON/D-ON
Hysteresis
Allows the selection of hystere-
sis level. (Refer to p.27)
Stability
Permits selection of stability indicator
response levels for changes in the
range for lighting up. (Refer to p.28)
ECO Mode Setting
Sets the digital display to turn
off automatically.
(Refer to p.35~)
Remote Data Bank Save
Using
optical
communications,
configuration settings can be saved into
data banks, in a single step. (Refer to p.44)
Test
Verifies whether optical communications
have been properly established.
(Refer to p.45)
Adjust Lock
Allows fine adjustment of the 'threshold
value' to be directly performed during
RUN mode. (Refer to p.51)
Reset
All settings, except for data
bank information, revert to
factory settings. (Refer to p.52)