Function Assignment Of External Terminal And Control; Input Terminal Function Selection (Pr. 178 To Pr. 184) - Mitsubishi Electric FR-E720-0.1K(SC) Instruction Manual

Fr-e700 series
Table of Contents

Advertisement

4.11 Function assignment of external terminal and control

Purpose
Assign function to input terminal
Set MRS signal (output shutoff) to
NC contact specification
Assign start signal and forward/
reverse command to other signals
Assign function to output terminal
Detect output frequency
Detect output current
Remote output function

4.11.1 Input terminal function selection (Pr. 178 to Pr. 184)

Use these parameters to select/change the input terminal functions.
Parameter
Name
Number
STF terminal function
178
selection
STR terminal function
179
selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
MRS terminal function
183
∗3
selection
RES terminal function
184
selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 188)
∗1
The setting value of "60" is available for Pr. 178 only.
∗2
The setting value of "61" is available for Pr. 179 only.
∗3
For the safety stop function model, this setting is active only during the communication operation. (
(1)
Input terminal function assignment
Using Pr. 178 to Pr. 184, set the functions of the input terminals.
Refer to the following table and set the parameters:
Setting
Signal
Pr. 59 = 0 (initial value)
0
RL
Pr. 59 = 1, 2 ∗1
Pr. 270 = 1 ∗2
Pr. 59 = 0 (initial value)
1
RM
Pr. 59 = 1, 2 ∗1
Pr. 59 = 0 (initial value)
2
RH
Pr. 59 = 1, 2 ∗1

Function assignment of external terminal and control

Parameter that should be Set
Input terminal function
selection
MRS input selection
Start signal (STF/STR)
operation selection
Output terminal function
assignment
Up-to-frequency
sensitivity
Output frequency
detection
Output current detection
Zero current detection
Remote output
Initial
Initial Signal
Value
60
STF (forward rotation command)
61
STR (reverse rotation command)
0
RL (low-speed operation command)
RM (middle speed operation
1
command)
RH (high-speed operation
2
command)
24
MRS (output stop)
62
RES (inverter reset)
Function
Low-speed operation command
Remote setting (setting clear)
Stop-on contact selection 0
Middle-speed operation command
Remote setting (deceleration)
High-speed operation command
Remote setting (acceleration)
Pr. 178 to Pr. 184
Pr. 17
Pr. 250
Pr. 190 to Pr. 192
Pr. 41 to Pr. 43
Pr. 150 to Pr. 153
Pr. 495 to Pr. 497
Setting Range
0 to 5, 7, 8, 10, 12, 14 to 16, 18,
24, 25, 60∗1, 61∗2, 62, 65 to 67,
9999
Refer to page 211
)
Related Parameters
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27
Pr.232 to Pr.239
Pr. 59
Pr. 270, Pr. 275, Pr. 276
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Refer to Page
139
141
143
145
149
150
152
4
Refer to
Page
102
106
133
102
106
102
106
139

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents