Parameter list
Func-
Parameter
Name
tion
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
563
Energization time carrying-over times
564
Operating time carrying-over times
571
Holding time at a start
611
Acceleration time at a restart
653
Speed smoothing control
Regeneration avoidance frequency
665
gain
800
Control method selection
859
Torque current
872
Input phase loss protection selection
∗13
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance compensation
885
frequency limit value
886
Regeneration avoidance voltage gain
888
Free parameter 1
889
Free parameter 2
C0
FM terminal calibration
(900)
∗10
C1
AM terminal calibration
(901)
∗10
C2
Terminal 2 frequency setting bias
(902)
frequency
∗10
C3
Terminal 2 frequency setting bias
(902)
∗10
125
Terminal 2 frequency setting gain
(903)
frequency
∗10
C4
Terminal 2 frequency setting gain
(903)
∗10
C5
Terminal 4 frequency setting bias
(904)
frequency
∗10
C6
Terminal 4 frequency setting bias
(904)
∗10
126
Terminal 4 frequency setting gain
(905)
frequency
∗10
C7
Terminal 4 frequency setting gain
(905)
∗10
76
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0.1 to 1.0s
0.1s
1s
269
0 to 20s
0.1s
0s
269
Rated
0 to 500A
0.01A
inverter
269
current
(0 to 65535)
1
0
154
(0 to 65535)
1
0
154
0 to 10s, 9999
0.1s
9999
112
0 to 3600s, 9999
0.1s
9999
162
0 to 200%
0.1%
0
175
0 to 200%
0.1%
100
261
84, 86,
20, 30
1
20
89
0 to 500A (0 to ****) ,
0.01A (1)
9999
120
∗6
9999
∗6
0, 1
1
1
172
0, 1, 2
1
0
261
400VDC/
300 to 800V
0.1V
261
780VDC
∗5
0 to 10Hz, 9999
0.01Hz
6Hz
261
0 to 200%
0.1%
100%
261
0 to 9999
1
9999
271
0 to 9999
1
9999
271
160
0 to 400Hz
0.01Hz
0Hz
179
0 to 300%
0.1%
0%
179
0 to 400Hz
0.01Hz
60Hz
179
0 to 300%
0.1%
100%
179
0 to 400Hz
0.01Hz
0Hz
179
0 to 300%
0.1%
20%
179
0 to 400Hz
0.01Hz
60Hz
179
0 to 300%
0.1%
100%
179
Customer
Parameter
Remarks
Setting
555
556
557
563
564
571
611
653
665
800
859
872
882
883
885
886
888
889
C0
(900)
C1
(901)
C2
(902)
C3
(902)
125
(903)
C4
(903)
C5
(904)
C6
(904)
126
(905)
C7
(905)
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
37
B7
5
38
B8
5
39
B9
5
3F
BF
5
40
C0
5
47
C7
5
0B
8B
6
35
B5
6
41
C1
6
×
00
80
8
3B
BB
8
×
48
C8
8
52
D2
8
53
D3
8
55
D5
8
56
D6
8
58
D8
8
59
D9
8
5C
DC
1
5D
DD
1
5E
DE
1
5E
DE
1
5F
DF
1
5F
DF
1
60
E0
1
60
E0
1
61
E1
1
61
E1
1
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
×
×
×
×
×
×
×
×
×
×
×
4
×
×
×
×
×
×
×

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric FR-E720-0.1K(SC)

Comments to this Manuals

Symbols: 0
Latest comments: