Mitsubishi Electric FR-E720-0.1K(SC) Instruction Manual page 144

Fr-e700 series
Table of Contents

Advertisement

Function assignment of external terminal and control
(2)
Three-wire type (STF, STR, STOP signal)
The three-wire connection is shown below.
Turning the STOP signal ON makes start self-holding function valid. In this case, the forward/reverse rotation signal
functions only as a start signal.
If the start signal (STF or STR) is turned ON and then OFF, the start signal is held and makes a start. When changing the
direction of rotation, turn STR (STF) ON once and then OFF.
To stop the inverter, turning off the STOP signal once decelerates it to a stop.
When using the STOP signal, set "25" in Pr. 178 to Pr. 184 to assign function.
Forward
Stop
rotation start
Reverse
rotation start
Forward
rotation
Reverse
rotation
ON
STF
STR
STOP ON
3-wire connection example (Pr. 250 = "9999")
REMARKS
When the JOG signal is turned ON to enable Jog operation, the STOP signal becomes invalid.
If the MRS signal is turned ON to stop the output, the self-holding function is not canceled.
(3)
Start signal selection
STF
STR
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Parameters referred to
Pr. 4 to Pr. 6 (multi-speed setting)
Pr. 178 to Pr. 184 (input terminal function selection)
144
STF
Inverter
STR
STOP
SD
Time
ON
OFF
OFF
Pr. 250 Setting Inverter Status
0 to 100s, 9999
Stop
Reverse rotation
Forward rotation
Stop
Refer to page 102
Refer to page 139
Stop
Start
Forward rotation
/reverse rotation
Forward
rotation
Reverse
rotation
ON
STF
ON
STR
STOP ON
3-wire connection example (Pr. 250 = "8888")
1000s to 1100s 8888
Stop
Forward rotation
Reverse rotation
STF
Inverter
STOP
STR
SD
Time
ON
OFF
OFF