4.20.7 USB communication (Pr. 547, Pr. 548)

Inverter setup can be easily performed using the FR Configurator by connecting the inverter and personal computer
with a USB cable.
A personal computer and inverter can be easily connected with one USB cable.
Parameter
Name
Number
USB communication
547∗
station number
USB communication
548∗
check time interval
∗ Changed setting value is valid when powering on or resetting the inverter.
USB communication specifications
Interface
Conforms to USB1.1
Transmission
12Mbps
Speed:
Wiring Length
Maximum 5m
Connector
USB mini B connector (receptacle mini B type)
Power supply
Self-power supply
You can perform parameter setting and monitoring with the FR Configurator. Refer to the instruction manual of the FR
Configurator for details.
REMARKS
USB cable available on the market
Name
USB cable
Parameters referred to
Pr. 551 PU mode operation command source selection
Initial Value
0
9999
USB connector
USB cable
<How to open the USB connector cover>
Pull the cover in the direction of arrow.
Model
MR-J3USBCBL3M
Connector for amplifier
mini-B connector (5 pin)
Cable length 3m
Refer to page 205
Communication operation and setting
Setting Range
0 to 31
Inverter station number specification
USB communication is possible
0
Trips in the PU operation mode (E.USB)
Sets the interval of communication check time.
If a no-communication state persists for longer
0.1 to 999.8s
than the permissible time, the inverter trips
(E.USB).
9999
No communication check
Application/Specifications
Connector for personal computer
A connector
Description
Then turn it upward.